facebook instagram Whatsapp
Certified Master Roofers in Metro Vancouver

No worries. Let's try it this way

Please fill your details, and we will provide you with an estimate in a very timely manner.

Burnaby, BC · Commercial Roofing

Torch-On Roofing in Burnaby, BC

A roofer heat-applying a torch-on membrane on a flat roof, with a second worker standing by a fire extinguisher

Torch-on names an application method, and it covers less of the roof than the name suggests. Canadian industry guidance is to keep the flame away from the details where rooftop fires most often begin. A roof built to that advice carries two methods: one across the open field, another at its edges and openings. GoodVans Roofing takes on torch-on roofing across Burnaby's commercial and industrial property, and the question worth settling early on any of it is which parts of a roof heat belongs on.

What the name actually describes

Modified bitumen is a family of membranes. Torch-on is one route onto a building: a propane flame warms the sheet from below as it is unrolled, softening the bitumen so it grips the surface prepared for it. Other members of the same family reach the roof cold-applied or self-adhered, so the two terms are not interchangeable.

Something less obvious follows. Adhesion on this system is created in place, against whatever surface is actually there, rather than arriving finished in the roll. Weighing torch-on against the other shallow-pitch options belongs with low-slope roofing in Burnaby.

A torch flame softening the underside of a modified bitumen roll as it is unrolled

The bond, and where it is not made with a flame

Adhesion is capped by the surface beneath it, which puts preparation ahead of its position in the programme. GoodVans Roofing readies a surface by cleaning it and priming it — the primer is what gives softened bitumen something to key into — and how much either takes follows from the surface found.

Overlaps come next, turning separate sheets into one skin, and they account for a serious portion of the installation.

Against all that, the Canadian Roofing Contractors' Association advises against depending on the flame where the risk concentrates. Its guidance is to form perimeters, penetrations and flashings with flameless products instead, carried into the field before any torched membrane reaches them.

A roofer rolling primer onto a flat roof deck

Penetrations, perimeters and where fires start

Drains, vents, curbs and equipment feet all interrupt the field, and each interruption needs sealing and working back in so the surface reads as one. Condition at those points drifts away from the field's.

And they matter twice. The CRCA bulletin places most torch-related rooftop fires at membrane flashings, perimeters and penetrations — the same details that are hardest to form well. It also notes that fire can be drawn into joints between materials and into interior spaces by pressure difference, which makes what sits behind a detail a question about the work, not only about the roof.

Standing water loads these details as well.

A roofer sealing torch-on membrane at the base of a rooftop curb

Assessing a torch-on roof that is already there

When a torch-on roof starts causing trouble, the division that pays is between the torched field and the detail work around it. The two go wrong for different reasons and they lead to different scopes.

Worth pinning down: how far the trouble extends, and whether the places it appears have anything in common; which part is implicated, field or detail; what state the membrane beside it is in; what drainage is doing; and what is found under the membrane, since that governs what new work would mean. Parts of it stay out of sight until an area is opened up.

What widens the scope, and what does not

Maintenance, repair and new installation are all within what GoodVans Roofing does on torch-on roofs, so none of the three is a foregone conclusion.

Contained work suits a fault with boundaries, an identified cause, and the membrane and detailing beside it in sound order. That same fault turning up in several unconnected places is a different reading of the roof.

Reasons to widen: that scatter; drainage that no amount of surface work will fix; or something below the membrane raising questions of its own. No percentage of the area and no number of years decides it. A repair method also has to suit the system already up there; that a roof is torch-on does not settle how it should be repaired.

Two routes that sit between

A coating treats a system that stays where it is, and GoodVans Roofing applies coatings on commercial and industrial roofs — though what is underneath decides whether one is appropriate, and assessment settles that. Roof coatings and waterproofing in Burnaby covers it.

Where the question is how a roof is trending rather than what one symptom means, roof asset management in Burnaby is the ground for that.

Inside a torch-on roofing project in Burnaby

A GoodVans Roofing torch-on project opens with an inspection — there to establish whether torch-on suits the roof already in place — and moves through preparation and priming, membrane bonded a section at a time, seams checked and the roof water-tested before close-out, then a cleared site with the result reviewed alongside the client and maintenance advice to go with it. What each stage takes depends on the roof.

Because a heat source is involved, the BC Fire Code counts this as hot work — a classification attaching to the activity rather than to the membrane, and one whose practical consequences are worked out for a given site before anyone starts.

A roofer in a hard hat checking a seam on a finished torch-on roof

Common questions

Is the whole roof torched?

Not necessarily, and worth asking a proposal about. Industry guidance is to keep open flame away from flashings, perimeters and penetrations and to form those with flameless products set into the field, so many torch-on roofs combine methods by design rather than by compromise.

Our deck is wood. Does that rule torch-on out?

It bears directly on where heat can be used. The CRCA advises against torching on wood substrates and decks, noting that wood stays susceptible even where non-combustible material covers it. Whether that limits the method at the details, across the roof, or not at all is established by assessing the assembly.

Is torch-on work treated differently from other roofing work on site?

In one respect. Roofing that involves a heat source counts as hot work under the BC Fire Code, which brings the Code's hot-work provisions into the job. What follows for a particular building is worked out beforehand rather than assumed.

What should a torch-on proposal say about the details?

How perimeters, penetrations and flashings will be formed, and what sits under them. That is where the method varies, where fire risk concentrates during installation, and where condition later diverges from the field — so a proposal describing only the membrane has described the part that varies least.

Starting with where the trouble is

A problem on a torch-on roof sits somewhere specific — the field, a lap, a termination, the drainage — and locating it is what fixes the size of the job. Book an assessment to do that, or see what GoodVans Roofing's torch-on roofing work covers.

Let's talk

Contact Info

  • Address GoodVans Roofing 207 W Hastings St, Unit 1210, Vancouver, BC V6B 1H7, Canada
  • Contact Number 17783778209
  • Email ID info@gvroofs.ca
facebook instagram Whatsapp