Torch-On Roofing in Surrey, BC
"Torch-on" tells you how a roofing sheet is put down. It says much less about the sheet. Two quotes promising torch-on roofing can specify different membranes: another modifier, reinforcing mat, top surface or number of plies. In Surrey, GoodVans Roofing installs new torch-on roofing and repairs and maintains existing torch-on roofs on commercial and industrial buildings. A useful proposal names what is being torched as clearly as how.
A method applied to a product
Torch-on is an application method for modified-bitumen membranes. The underside of each sheet is heated with a propane torch so the bitumen softens and bonds to what lies beneath and to the adjoining sheet.
The product is a separate question. Modified bitumen is asphalt blended with a polymer modifier. SBS (styrene-butadiene-styrene) gives a rubber-like, flexible membrane, and it is the type GoodVans Roofing's torch-on materials page describes. APP (atactic polypropylene) gives a stiffer, plastic-modified sheet. Neither modifier means torch-on by itself: SBS membranes are also made for self-adhered, cold-process and other applications.
Choosing between modified bitumen and other low-slope systems belongs to low-slope roofing in Surrey.
Base sheet, cap sheet and what each carries
Many torch-on roofs are built as two plies. The base sheet is the lower ply. Depending on the manufacturer's system, it may be torch-applied, mechanically fastened or self-adhered, so not every base sheet is torched or bonded directly to the surface below. The cap sheet is torched over it and becomes the exposed weathering layer, so manufacturers typically surface it with mineral granules. The laps of the two plies are typically offset rather than stacked.
Each sheet carries a reinforcing mat, commonly polyester, glass fibre or a composite.
On a finished roof the cap sheet's surfacing can often be seen, but the reinforcement, the polymer formulation and the plies beneath cannot reliably be identified from the surface. The specification should therefore state the modifier, reinforcement, surfacing and number of plies; those details matter again at the first repair.
Where flame-applied sheets meet details
Drains, vents, curbs, parapets and equipment supports each interrupt the membrane, and flashings there are often built from base and cap flashing sheets.
Not every detail suits a flame. Where combustible materials or concealed cavities lie close to the work, or a manufacturer's instructions call for it, a self-adhered or cold-applied product from the same family may be used instead.
Standing water over details and laps adds demand too. Whether it matters depends on the drainage arrangement, the roof's geometry, the seam detailing and what the membrane manufacturer allows, and its presence alone does not establish a failure.
Reading an existing torch-on roof
First establish what is already there. How many plies? What is the cap sheet surfaced with, and is the surfacing intact? Are problems in one area or several, and in the laps and flashings or the field?
Records such as original specifications or product data help; otherwise a small test opening by qualified roofers can show the plies and what lies beneath. The membrane surface cannot show the condition of the insulation or deck below, and some conditions only become apparent once an area is opened.
Matching repair to the membrane already there
GoodVans Roofing repairs, maintains and installs torch-on roofs, so no route is presumed before assessment.
A repair has to suit the membrane it joins. New material needs to be compatible with the existing modifier and surfacing, and an aged or weathered cap sheet may need preparation before anything will bond to it reliably. A contained repair can fit where the defect has clear limits and the surrounding plies, laps and details are sound.
Scattered faults, falls only rebuilding would fix, or doubts about the layers underneath point toward a broader scope. Not every defect can be repaired locally.
Other routes to consider
Protecting the existing membrane depends on its condition and coating compatibility; see roof coatings and waterproofing in Surrey. For tracking condition across years, roof asset management plans in Surrey is the route.
How GoodVans Roofing approaches torch-on work
GoodVans Roofing assesses the laps, terminations and membrane together before setting a torch-on scope. On a replacement, the existing assembly is identified first, then what comes off is agreed, the exposed surface is reviewed, and new membrane is tied in at each termination. Seam checks and a leak test close out the work.
Torch application is hot work, and its fire risk is managed at several levels. As general practice, torch work belongs with crews trained in it, and combustible materials may be concealed before work begins. Manufacturers set their own limits, including surfaces their products should not be torched to. Each site then needs its own fire-safety planning, covering protection where heat meets combustible materials and any fire-watch arrangements the applicable requirements call for. For roofs under the RCABC's RoofStar guarantee, its SBS Roof Systems Standard includes a fire watch in its fire safety plan provisions and lets a design authority require its Hot Works Program; that applies within the programme, not to every roof.
Torch-on roofing questions from Surrey building owners
What does "SBS" on a torch-on quote tell us?
That the membrane's bitumen is modified with styrene-butadiene-styrene, a rubber-like polymer that gives the sheet flexibility. It describes the material, not the method.
Our quote lists a base sheet and a cap sheet. Why two?
The two plies do different jobs. The base sheet is the lower ply, attached by whichever method the manufacturer's system allows, and the cap sheet forms the exposed, usually granule-surfaced, top layer, with its laps offset from the base sheet's. The right number of plies depends on the system specified and the manufacturer's requirements.
Granules from our roof are collecting at the drains. Should we be concerned?
Granules protect the cap sheet's bitumen, so loss across an area can indicate surface wear. It does not by itself prove a leak, and some loose granules can be expected on a newer roof. Assessment shows whether the loss is local or widespread.
Does a repair have to use the same product as the original roof?
Not always the identical product. Repair materials have to be compatible with the existing membrane, and where heat is unsuitable at a particular spot, a non-torch product from the same family may serve. Whether it holds depends on the existing membrane's condition and manufacturer requirements.
Starting with what is on the roof
Whether a torch-on roof is giving trouble or being specified, start with which membrane is involved and where any problem sits. Book a torch-on roof assessment with GoodVans Roofing, or see the torch-on roofing service for the work it covers.